Sonography Principles and Instrumentation Questions and Answers

Question 1

What is the benefit of using a wall filter?

Options:

A.

Reduces aliasing

B.

Increases velocity range

C.

Increases signal-to-noise ratio

D.

Removes low-frequency signals

Question 2

Which artifact occurs when there is increased amplification of reflectors distal to a low-attenuating structure?

Options:

A.

Mirror image

B.

Enhancement

C.

Reverberation

D.

Refraction

Question 3

Which image demonstrates appropriate spectral Doppler gain?

as

Options:

A.

Option A

B.

Option B

C.

Option C

D.

Option D

Question 4

What is the effect of an increased aperture in a linear array transducer?

Options:

A.

Deeper focus

B.

Improved axial resolution

C.

Shorter near-field length

D.

Decreased temporal resolution

Question 5

What is an advantage of using pulsed wave Doppler as compared to using continuous wave Doppler?

Options:

A.

Higher echo sensitivity

B.

Ability to select sample depth

C.

Decreased display of aliasing

D.

Improved temporal resolution

Question 6

What would increase with an increase in acoustic power?

Options:

A.

Frequency

B.

Impedance

C.

Thermal Index

D.

Wavelength

Question 7

What are two types of cavitation in tissue?

Options:

A.

Heat and transient

B.

Thermal and mechanical

C.

Stable and transient

D.

Thermal and stable

Question 8

What is ensemble length (packet size)?

Options:

A.

Length of pulses per scan line

B.

Number of pulses along a scan line

C.

Amplitude of pulses along the scan line

D.

Velocity of pulses along the scan line

Question 9

For harmonic imaging, what must the overall transducer bandwidth contain?

Options:

A.

Fundamental and second harmonic frequencies

B.

Fundamental and fourth harmonic frequencies

C.

Fundamental and even harmonic frequencies

D.

Fundamental and odd harmonic frequencies

Question 10

What is effected by increasing the color scale?

Options:

A.

The Nyquist limit is increased

B.

More colors are displayed

C.

The color box width decreases

D.

The color priority decreases

Question 11

What parameter change reduces spectral Doppler aliasing?

Options:

A.

Increase Doppler angle

B.

Change color scale

C.

Decrease pulse repetition frequency

D.

Utilize m-mode

Question 12

Which gray-scale artifact occurs when a structure attenuates less than the adjacent tissues?

Options:

A.

Enhancement

B.

Range ambiguity

C.

Refraction

D.

Shadowing

Question 13

The calipers in this image measure which performance characteristic of a system?

as

Options:

A.

Depth measurement accuracy

B.

Dynamic range

C.

Axial resolution

D.

Lateral resolution

Question 14

Which characteristic of ultrasound transmission is directly proportional to an increase in frequency?

Options:

A.

Wavelength

B.

Pulse duration

C.

Attenuation

D.

Penetration

Question 15

Which system control adjusts amplification of signals as a function of depth?

Options:

A.

Output power

B.

Time gain compensation

C.

Transmit focus

D.

Reject

Question 16

What is the effect of increasing the sample volume on the spectral Doppler signal tracing?

Options:

A.

Decreased sweep speed

B.

Increased noise

C.

Increased velocity sensitivity

D.

Decreased aliasing

Question 17

What causes color flash artifact?

Options:

A.

Aliasing

B.

Tissue motion

C.

High velocity blood flow

D.

Strong reflector

Question 18

What affects lateral resolution?

Options:

A.

Frame rate

B.

Focal zone

C.

Duty factor

D.

Spatial pulse length

Question 19

Which index is related to the likelihood of cavitation?

Options:

A.

Thermal

B.

Temporal

C.

Mechanical

D.

Acoustical output

Question 20

How is the wavelength affected when switching from a 10 MHz transducer to a 5 MHz transducer?

Options:

A.

Halves

B.

Quarters

C.

Quadruples

D.

Doubles

Question 21

Which structure can be evaluated using M-mode?

Options:

A.

Heart

B.

Liver

C.

Kidneys

D.

Pancreas

Question 22

Which factor causes posterior acoustic enhancement?

Options:

A.

High-frequency transducer

B.

Low-frequency transducer

C.

Strongly attenuating structure

D.

Weakly attenuating structure

Question 23

While imaging at a depth of 2 cm, which adjustment would improve the axial resolution?

Options:

A.

Turn off spatial compounding

B.

Turn on harmonics

C.

Decrease gain

D.

Increase frequency

Question 24

What reduces speckle and increases visualization of specular reflectors and attenuated structures?

Options:

A.

Elastography

B.

Extended field of view

C.

Pixel interpolation

D.

Spatial compounding

Question 25

Which color Doppler setting can be optimized to eliminate low-frequency Doppler shifts without having any effect on higher Doppler frequency shifts?

Options:

A.

Gain

B.

Scale

C.

Wall filter

D.

Persistence

Question 26

Which factor does a string phantom evaluate?

Options:

A.

Two-dimensional resolution

B.

Intensity values

C.

Flow velocity

D.

Slice thickness

Question 27

Which unfocused transducer will have the greatest divergence?

Options:

A.

4 mm aperture, 4 MHz

B.

4 mm aperture, 6 MHz

C.

6 mm aperture, 4 MHz

D.

6 mm aperture, 6 MHz

Question 28

Which spectral Doppler finding can occur when using a low pulse repetition frequency setting?

Options:

A.

Spectral broadening

B.

Range ambiguity

C.

Aliasing

D.

Dropout

Question 29

Which component of a contrast agent causes a marked mismatch in impedance between the agent and blood?

Options:

A.

Viscous liquid

B.

Serous liquid

C.

Solid

D.

Gas

Question 30

What device is used to determine axial resolution?

Options:

A.

Tissue-mimicking phantom

B.

Hydrophone

C.

Beam profiler

D.

Doppler phantom

Question 31

Which factor determines elevational resolution?

Options:

A.

Beam depth

B.

Beam thickness

C.

Beam uniformity ratio

D.

Beam width

Question 32

Which color Doppler control allows for reassignment of red and blue to represent flow direction?

Options:

A.

Color priority

B.

Color gain

C.

Color threshold

D.

Color invert

Question 33

Increasing which setting could enhance the visibility of acoustic shadowing posterior to a calcified object?

Options:

A.

Gain

B.

Output power

C.

Dynamic range

D.

Frequency

Question 34

Which Doppler control adjustment could eliminate the end-diastolic velocity in the Doppler spectrum?

Options:

A.

Increased Doppler gain

B.

Increased packet size

C.

Increased velocity scale

D.

Increased wall filter

Question 35

What does changing the displayed depth control directly affect?

Options:

A.

Pulse repetition frequency

B.

Transducer transmit frequency

C.

Pulse duration

D.

Spatial pulse length

Question 36

Which of these modes has the highest duty factor?

Options:

A.

Continuous wave Doppler

B.

Pulsed wave Doppler

C.

Color flow Doppler

D.

Gray-scale

Question 37

Which characteristics are associated with an ideal imaging transducer?

Options:

A.

Narrow bandwidth; high quality factor

B.

Broad bandwidth; low quality factor

C.

Narrow bandwidth; low quality factor

D.

Broad bandwidth; high quality factor

Question 38

What is the result of increasing the wall filter setting during Doppler sampling?

Options:

A.

Diminished aliasing

B.

Decreased bandwidth

C.

Creation of spectral broadening

D.

Reduced display of low-frequency shifts

Question 39

What happens to the amount of attenuation if the path length is doubled?

Options:

A.

Quadrupled

B.

Doubled

C.

Halved

D.

Quartered

Question 40

Which adjustment resulted in the change from image A to image B?

as

Options:

A.

Increased transmit frequency

B.

Increased scale

C.

Decreased color gain

D.

Decreased acoustic power

Question 41

Which statement characterizes the primary difference between image A and image B?

as

Options:

A.

Image A demonstrates a better axial resolution.

B.

Image A demonstrates a lower overall gain setting.

C.

Image A demonstrates a shallower field of view.

D.

Image A demonstrates a wider scale of contrast.

Question 42

Which adjustment can maintain the same frame rate when the depth is increased?

Options:

A.

Increase number of focal zones

B.

Decrease image width

C.

Increase frequency

D.

Decrease persistence

Question 43

Which type of resolution is improved by transmit focus?

Options:

A.

Elevational

B.

Axial

C.

Lateral

D.

Temporal

Question 44

What determines the resonant frequency of a pulsed wave transducer?

Options:

A.

Element thickness and pulse repetition frequency

B.

Element diameter and speed of sound in element

C.

Element diameter and element thickness

D.

Element thickness and speed of sound in element

Question 45

Penetration can be improved by decreasing which setting?

Options:

A.

Output power

B.

Frequency

C.

Gain

D.

Sector width

Question 46

What is a potential negative consequence of using a high wall filter?

Options:

A.

Desired signal may be eliminated

B.

Aliasing could occur

C.

Penetration is reduced

D.

Too much noise may appear on the image

Question 47

Which color control was adjusted in color bar A to produce color bar B?

as

Options:

A.

Baseline

B.

Scale

C.

Map

D.

Invert

Question 48

What happens to the Doppler shift when the angle is changed from 30 to 60 degrees?

Options:

A.

No significant change

B.

Loss of Doppler signal

C.

Increases

D.

Decreases

Question 49

Which resolution is degraded when utilizing multiple transmit focal zones?

Options:

A.

Temporal

B.

Lateral

C.

Axial

D.

Elevational

Question 50

During a color Doppler scan, which angle to flow would most likely result in no color being visualized?

Options:

A.

3 degrees

B.

45 degreesC 88 degrees

C.

175 degrees

Question 51

What information does the ultrasound system calculate to display color flow?

Options:

A.

Peak Doppler frequency

B.

Mean Doppler frequency

C.

Peak velocity of flow

D.

Minimum velocity of flow

Question 52

During 3-D volume acquisition, the quality of the images is most dependent upon which factor?

Options:

A.

Number of slices acquired

B.

Power output

C.

Rendering method utilized

D.

Speed of post-processing image compression

Question 53

Which factor will improve axial resolution?

Options:

A.

Increasing the focal zone

B.

Reducing the number of cycles per pulse

C.

Changing the gray-scale map

D.

Decreasing the frame rate

Question 54

Which factor improves axial resolution?

Options:

A.

Shorter spatial pulse length

B.

Lower frequency transducer

C.

Narrower beamwidth

D.

Decreased compression

Question 55

Which ultrasound adjustment allows for an increased frame rate in color flow Doppler?

Options:

A.

Using continuous wave Doppler

B.

Decreasing depth

C.

Using multiple focal zones

D.

Increasing sector scan width

Question 56

Which is a method to reduce noise?

Options:

A.

Increase frequency

B.

Decrease beam width

C.

Decrease depth

D.

Increase persistence