HPE Network Campus Access Professional Architect Exam Questions and Answers
Following your initial meeting with the customer, which questions must you be able to answer?
Choose two.
Because of the transport type used between regional data centers, the client is experiencing consistently delayed data transmissions. Response time between the locations remains around 200 ms.
How would this phenomenon be classified?
Original exhibit — Question 8

What should be considered when using existing MMF and upgrading to equipment capable of 10 GbE speeds?
Choose two.
Manufacturing A.B.C. is a mid-sized international company that specializes in manufacturing industrial equipment. It has operated in the market for more than two decades and has become a reputable participant in its industry. However, rapid technological advances have left its existing network infrastructure outdated and unable to keep pace with modern manufacturing-process demands.
Manufacturing A.B.C.'s network combines legacy wired and wireless components from multiple vendors, resulting in frequent downtime and reduced production efficiency. The aging equipment causes slow data-transfer rates, unreliable connectivity, and greater exposure to cyber threats. Fiber cabling must also be upgraded because OM2 is used for most of it.
Further compounding the network problems, the CTO's recent departure has left the company without a clear direction for the network-refresh project. The management team lacks consensus on the upgrade's scope, budget, and timeline.
The manufacturing customer's primary objectives are as follows:
Improve network performance and reliability to enhance production processes and minimize downtime.
Enhance network security to safeguard sensitive data and intellectual property.
Streamline communication and collaboration among the organization's different departments.
Ensure scalability to support future growth and technological advances.
Manufacturing A.B.C. requires a comprehensive network refresh with these components:
Upgrade the wired infrastructure to high-speed Ethernet switches to support increased data-transfer rates and reduce latency.
Implement a robust wireless solution with enterprise-grade access points that provides seamless connectivity throughout the manufacturing facility.
Use centralized network-management tools to simplify network administration and monitoring.
Expectations:
The customer expects the network-refresh project to be completed efficiently, with minimal disruption to ongoing operations. They seek a reliable, experienced network-solutions provider that understands their specific manufacturing requirements and can deliver a customized solution consistent with their budget constraints. Given the recent CTO change, the manufacturing customer is eager to receive clear project proposals and decision-making support.
As a network-solutions provider, your role is to address these concerns, provide expert guidance, and present a clearly defined plan to meet the objectives effectively.
Manufacturing A.B.C. must regulate various traffic types with QoS, and the architect chose DWRR instead of SP queuing. Which switches support DWRR?
Choose two.
A large multinational financial institution has engaged you to design a new full-stack wired and wireless network for its new 6-story regional office building. The facility’s bottom two floors will be retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). Data centers are all offsite and are out of scope for this project. The customer is underserved by its current L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge.
The retail space will provide public guest Wi-Fi access. Retail associates will use corporate tablets for customer service, with a mix of wired and wireless devices throughout the retail floors. Corporate users will mainly use wireless connectivity, although several wired clients, printers, and hard VoIP phones will also be used.
The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services.
The client wants to provide Blue Dot wayfinding for its carpeted office space. The retail floors are not currently in scope.
What is required to ensure the solution is properly licensed?
Refer to the exhibit.
Original HPE Aruba Networking SSE architecture exhibit

Match the HPE Aruba Networking (ANW) Secure Service Edge (SSE) cloud services with the appropriate descriptions.

You are responding to a customer’s Request for Proposal (RFP) for a new network-infrastructure solution. The RFP describes the customer’s desired features and technical outcomes but does not specify several important design details.
At this point in the proposal process, you must document the assumptions made to complete the design and address gaps in the RFP. These assumptions should represent reasonable expectations that guide the customer’s understanding of the solution and highlight areas that may require further clarification.
What is a valid example of an assumption that should be presented to the customer in your RFP response?
You are a member of a cross-functional team developing a detailed design proposal for a customer deploying EVPN-VXLAN in a modern campus core and data center fabric. The customer is moving from a traditional VLAN-based Layer 2 design to a VXLAN-based overlay architecture to support segmentation scalability and automation.
As the solution undergoes review, you are asked to contribute by identifying and explaining core technical behaviors and configuration considerations critical to the success of EVPN-VXLAN in this environment.
Which statements accurately describe key characteristics of EVPN-VXLAN in modern campus or data center networks?
A customer wants the ability to view network usage.
Which product would provide this visibility?
Match each deployment mode to its description.

Which statements correctly describe the Unified Communication (UCC) and Intelligent Call Handling (ICH) capabilities available in HPE Aruba Networking AOS-10, along with their associated subscription and configuration requirements?
Choose two.
A global cruise line company must refresh its current fleet. It will refresh the ship’s “insides” to be cost-effective and improve sustainability, replacing all WLAN/LAN hardware. During this refresh, the company will not change its existing security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will require a hardware refresh. They will begin with the smallest ship, with a maximum of 800 guests.
Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Each cabin and technical room receives one individual access switch.
The ship’s cabling infrastructure will not be refreshed. Every IDF is connected to the MDF by SMF, with two pairs available for the interconnect between core and distribution. The SM fiber between the MDF and IDF is less than 300 meters (980 ft) long and is OS1. Each cabin is connected to the IDF by one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room is connected to the IDF by one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft).
For every cabin/technical room, the customer wants to replace the existing fan-less 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and the technical rooms require redundant power.
The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN infrastructure uses 200/300 series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no WLAN requirement changes.
The cruise line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will provide 99.8% uptime, required to keep paid guest Wi-Fi operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed.
Based on best practices, what optic type should be recommended for the connection between the IDF and the technical rooms?
What is one scenario in which designing a 2-tier campus LAN is preferable to using a 3-tier design?
As part of several technical proposals for a customer deploying both Wi-Fi 7 high-throughput HD and very high-throughput VHD networks based on HPE Aruba Networking AOS-10, you are identifying key considerations for radio frequency (RF) design and channel optimization.
Which statements are recommended AOS-10 best practices for RF planning and should be included in your proposals to deliver optimal wireless performance?
Choose two.
A global cruise-line company needs to refresh its current fleet. It will refresh the ship’s internal infrastructure to be cost-effective and improve sustainability. It will replace all WLAN/LAN hardware on the ship. As part of this refresh, the company will not change its existing security requirements. The CIO also wants to minimize the number of unused switch ports. Any future expansion will always require a hardware refresh. The company will begin with the smallest ship, with a maximum of 800 guests.
Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Each cabin and technical room receives a single access switch.
The ship’s cabling infrastructure will not be replaced. Each IDF connects to the MDF over SMF, with two pairs available for the interconnect between core and distribution. The SMF length between the MDF and IDF is less than 300 meters (980 ft), and it is OS1 fiber. Each cabin connects to its IDF with one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to its IDF with one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft).
For every cabin and technical room, the customer wants to replace its current fanless 2530/2540 switches without changing the requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and the technical rooms require redundant power.
The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. Its WLAN infrastructure uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements.
The cruise-line company will replace its existing Internet connection before the LAN/WLAN refresh. The new Internet connection will offer 99.8% uptime, needed to keep paid guest Wi-Fi continuously operational. With this new Internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the Internet connection is guaranteed.
Based on best practices, what optic type should be recommended for the connection between the MDF and the IDFs?
You are developing a technical proposal for a customer that plans to deploy HPE Aruba Networking Cloud Central-managed AOS-10 Access Points in a typical campus office environment. The customer has used ARM-based radio resource management successfully for many years. During their transition to AOS-10, they ask for guidance on suitable initial EIRP (Effective Isotropic Radiated Power) values for new radio profiles in HPE Aruba Networking Central.
Which EIRP configuration option should be recommended as an appropriate starting point for this office deployment?
Which statements correctly describe valid high-availability features (VSX or VSF) for AOS-CX switches commonly deployed in enterprise campus environments?
Choose two.
Identify the stakeholders when collecting information for the network design and the new IDF/MDF design.
Choose two.
Match the Wi-Fi features to their corresponding standards. Matches may be used more than once.

XYZ Regional Hospital is an integrated healthcare system consisting of hospitals, neighborhood health centers, and small doctor offices. XYZ Regional Hospital recently merged with 4x neighborhood health centers and 125 doctor branch offices. Its wireless, wired-access, and AAA solutions are outdated and must be replaced.
XYZ Regional Hospital wants to future-proof and improve efficiency at all sites by enhancing wired and wireless access and moving to centralized, unified wired/wireless and policy management that provides uninterrupted availability of all systems.
Locations:
XYZ Regional Hospital is located in New York City
Dila Health Center is located in City A
Mount Health Center is located in City B
Rock Health Center is located in City C
Branch clinics are located at different locations across the United States
Requirements:
Provide, through management software, a single pane of glass to manage wired and wireless LANs and VPNs across campus, branch, and remote environments through a web/cloud architecture that provides near real-time insight, troubleshooting tools, and Service Level performance reporting.
Seamless integration across wired, wireless, WAN, SD-Branch, and IoT
Provide secure wireless access for all Regional Hospital employees and partners, and provide wireless Internet access to medical citizens when they visit our facilities.
All access points must support these features and specifications: 802.11 ax (Wi-Fi 6E Certified)
Security options including WP2/WPA3 and 802.1X with Radius secure authentication
Identify and authenticate every wireless and wired device
End-to-end role-based security
Seamless mobility throughout the hospital for medical teams, patients, and visitors
Reduce Wi-Fi deployment times from days to hours and enable Zero-Touch deployments across the site
Establish a resilient, future-ready network infrastructure with the intelligence, scalability, and intuitive toolsets to meet emerging needs
Fully redundant branch solution with dynamic path selection to the hospital
XYZ Regional Hospital plans a wireless site survey at its main campus. It must address recurring Wi-Fi coverage issues.
Which pieces of information are required?
Choose two.
Refer to the exhibit.
Original exhibit — Question 39

The exhibit shows an AOS-10 access point using VLAN 10 for management and a bridged wireless client receiving an IP address from VLAN 45, with the access switch carrying the client VLAN.
Your client is deploying an HPE Aruba Networking solution in which AOS-10 APs operate in bridged mode and connect directly to AOS-CX access switches in a campus environment.
A leading security priority is to block user traffic to any destination classified by BrightCloud Web Classification as “Bot Nets.” You have been asked to review and confirm the appropriate technical steps for accurate identification, classification, and blocking of this traffic through Central-managed policies and AOS-CX integration.
To block user access to the specified web destination(s) in this deployment model, which action should be taken?
Match each deployment type with its estimated number of APs.

The current IT staff is accustomed to working with legacy OS-S (ProCurve) equipment. They are concerned that the differing command syntax will prevent them from handling OS-CX switches.
Which two methods can make their transition easier? (Select two.)
Choose two.
Which licenses are required to use the UXI Client on Zebra devices?
Choose two.
Under which condition is a Mode Conditioning Patch Cable necessary?
A large multinational financial institution has hired you to design a new full-stack wired and wireless network for its new six-story regional office building. The bottom two floors will provide retail space for a large banking branch. The upper floors will be carpeted corporate office space, with each floor approximately 100,000 sq ft (9290 sq m). All data centers are offsite and outside this project’s scope. The customer is underserved by its existing L2-based network infrastructure and wants to use modern best practices in the new design. The network must be fully resilient and fault-tolerant, with dynamic segmentation at the edge.
The retail space will offer public guest Wi-Fi. Retail associates will use corporate tablets for customer service, and the retail floors will contain a mix of wired and wireless devices. Corporate users will primarily connect wirelessly, although several wired clients, printers, and hard VoIP phones will also be used.
The customer also plans to renovate the corporate office space to take advantage of 'smart office' technology. These enhancements will enable blue-dot wayfinding, presence analytics, and other location-based services.
The client wants redundant RADIUS resources in each of its three geographical regions (AMER, EMEA, and APAC). A large office location in each region has sufficient VMware resources available.
Each region has 5,000 clients, all of whom must perform either 802.1x wired or wireless authentication, as well as 802.1x authentication for one personal Wi-Fi device.
All non-personal devices must also validate health with a local agent.
An average of 500 guests are expected to be connected, with a maximum of 700 simultaneous connections using Guest Portal for Internet access.
TACACS authentication will also be configured for a total of 1,200 evenly distributed NADs.
To support virtual IPs and server redundancy in every region, how many Virtual Policy Manager Licenses are required?
You meet with a customer to update the network after the prior network manager has left the company for another role.
Which methods can validate the current network state when the available network documentation is invalid?
Choose two.
You are meeting with different stakeholders in a customer’s IT organization as part of an HPE Aruba Networking campus access-layer design project. You need to collect technical input that supports design decisions, including switch-port capacity, uplink requirements, and user-connectivity needs.
Which two stakeholders participate in these design activities?
Choose two.