Spring Sale Discount Flat 70% Offer - Ends in 0d 00h 00m 00s - Coupon code: 70diswrap

Huawei H13-624_V5.5 Dumps

Page: 1 / 13
Total 125 questions

HCIP-Storage V5.5 Questions and Answers

Question 1

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Question 2

An airport customer has purchased several Huawei OceanStor Pacific scale-out storage devices for service deployment. To ensure service reliability, an engineer has configured the HyperReplication feature on the storage devices and established a remote replication pair between the namespaces of the primary and secondary storage systems. Which of the following statements is true about the running statuses of the remote replication pair?

Options:

A.

If the running status of the remote replication pair is "Synchronizing", this indicates that data is being synchronized from the primary namespace to the secondary namespace. In this case, the engineer can enable the protection for secondary resources on the secondary storage system.

B.

If the running status of the remote replication pair is "Interrupted", this indicates that an internal I/O error has occurred or the remote replication link is down. As a result, the pair relationship is interrupted.

C.

If the running status of the remote replication pair is "Split", this indicates that the remote replication link is down or an internal I/O error has occurred. In this case, the pair cannot be synchronized or deleted.

D.

If the running status of the remote replication pair is "To be recovered", this indicates that the internal I/O error of the remote replication pair has been rectified. Data consistency between the primary and secondary storage systems is guaranteed by automatic synchronization.

Question 3

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

Options:

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Question 4

Huawei OceanStor Pacific series storage systems support the _______ client access mode. This mode allows a single client to connect to multiple storage nodes and supports MPI-I/O access. (Enter an acronym.)

Options:

Question 5

In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?

Options:

A.

Cache hit ratio of hot metadata

B.

CPU usage of metadata background management

C.

Whether failover is enabled for protocol receiving threads

D.

Hit ratio of the prefetch algorithm

Question 6

Which of the following statements are false about direct TCP offload engine (DTOE) 1.0? Select all that apply.

Options:

A.

This technology uses the polling mode, reducing the latency.

B.

This technology allows to directly operate the hardware queue in the user mode, avoiding the context switching overhead.

C.

High latency overhead still exists using the technology, such as kernel mode interrupts, locks, system calls, and thread switching.

D.

This technology requires CPU to process each MAC frame, which will consume a large number of CPU resources.

Question 7

Which of the following statements are false about the distributed parallel dlent (DPC) of Huawei scale-out storage products?

Options:

A.

If you want to reserve resources for deploying DPC, the available memory of compute nodes must be greater than or equal to 8 GB, and the memory reserved for the operating system must be greater than or equal to 4 GB.

B.

To enable the performance mode of CPUs, you can run the "cpupower frequency-set -g performance" command.

C.

If services running on DPC require higher performance, you can set CPUs to work in performance mode.

D.

DPC and non-uniform memory access (NUMA) are mutually exclusive. Therefore, the NUMA affinity tuning feature cannot be provided in actual scenarios.

Question 8

To power off a storage system, you need to stop host services, power off controller enclosures, and then disconnect external power supplies.

Options:

A.

TRUE

B.

FALSE

Question 9

In Huawei backup storage OceanProtect X3000, data reduction supports fixed-length (^duplication by default, but does not support variable-length (^duplication. Therefore, fixed-length ded11plication Is mainly used in the backup field.

Options:

A.

TRUE

B.

FALSE

Question 10

An industry customer has purchased several Huawei flash storage devices for service deployment. To improve service data reliability, an engineer configures the HyperReplication feature on the storage devices. If the engineer wants to modify the properties of a remote replication pair, which of the following commands cannot be used? (Choose all that apply)

Options:

A.

change hyper_metro_pair general

B.

change hyper_metro_pair start

C.

show consistency_group general

D.

change remote_replication synchronize

Question 11

In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.

Options:

A.

TRUE

B.

FALSE

Question 12

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Question 13

A school customer has purchased two Huawei flash storage devices and deployed them in different equipment rooms. To ensure data and service reliability, an engineer deploys the HyperReplication (remote replication) feature on the storage devices. After a fault recovery, the engineer needs to manually synchronize data to restore the pair relationship between the primary and secondary LUNs. What is the current running status of the remote replication pair?

Options:

A.

To be recovered

B.

Synchronizing

C.

Normal

D.

Split

Question 14

Huawel OceanStor Pacific series products provide object storage capabilities and support cross-site disaster recovery (DR). Which of the following statements about object storage cross-site DR is false?

Options:

A.

In cross-site DR cluster deployment mode, each site is independent. Specifically, it has an independent DeviceManager GUI and independent erasure code (EC) configuration.

B.

In backup and archiving scenarios that do not require a low latency, the redundancy mode between sites can be set to EC redundancy during cross site DR configuration.

C.

During cross-site DR configuration, if replicas are used for redundancy protection across sites, each site has complete object data.

D.

The cross-site DR of OceanStor Pacific series uses an asynchronous replication mechanism. The recovery point objective (RPO) is greater than 0, and the traffic control configuration cannot be adjusted.

Question 15

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O & M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Question 16

A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?

Options:

A.

The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.

B.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.

C.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.

D.

If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Question 17

A financial customer has purchased several Huawei OceanStor Pacific 9550 storage systems. When configuring basic object services on the storage systems, an engineer discovers that the object service cannot be enabled for storage nodes. Which of the following is not a possible cause?

Options:

A.

The engineer has manually adjusted the time of the cluster nodes. As a result, the conflict handling is different.

B.

NTP synchronization is not configured for the cluster, and different NTP time sources are used.

C.

Namespaces with the same name have been created under the same account.

D.

The Network Time Protocol (NTP) clock in the storage cluster is inconsistent with the clock of the client that accesses object services.

Question 18

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

Options:

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Question 19

A financial customer has purchased several Huawei OceanStor Dorado series storage devices for mission-critical service deployment. SmartMigration is configured to migrate services from a source LUN to a target LUN without interrupting host services. Which of the following statements about this feature is false?

Options:

A.

The implementation of a SmartMigration task between heterogeneous storage systems depends on the LUN takeover function provided by SmartVirtualization.

B.

When configuring this feature, you must plan the capacities of the source and target LUNs. The capacity of the target LUN must be greater than or equal to that of the source LUN.

C.

When configuring this feature, you cannot use a LUN that has been mapped to an application server as the target LUN of a SmartMigration task.

D.

The higher the migration rate, the better the host service performance is. Therefore, the highest migration rate can be used when the host service load is heavy.

Question 20

In a flash storage system, the ports of the cascading interface module or onboard cascading ports on the controller enclosure can only connect to port PI on the disk enclosure.

Options:

A.

TRUE

B.

FALSE

Question 21

The OceanStor Pacific series storage systems support the _______ feature. This feature uses the classic token bucket algorithm to control the traffic upper limit. If local tokens are insufficient, tokens are continuously generated and added to the token bucket based on the OPS and bandwidth upper limit of the corresponding QoS control object as the rate.

Options:

Question 22

A financial customer has purchased a Huawei flash storage system for service deployment. An engineer configures the HyperCDP feature on the storage system and wants to create a HyperCDP schedule. Which of the following commands can the engineer use?

Options:

A.

create hyper_cdp_schedule general

B.

add hyper_cdp_schedule fs

C.

create fs_hyper_cdp general

D.

change hyper_cdp_schedule enabled

Question 23

As a next-generation storage system, Huawei OceanStor Dorado series can focus on core enterprise services and meet enterprises’ service requirements. Which of the following statements are false about Huawei OceanStor Dorado series storage systems?

Options:

A.

The back-end shared interface module of OceanStor Dorado 18000 is inserted into the enclosure. The disk enclosure connected to the interface module can be accessed by controllers in the engine at the same time.

B.

Dorado V6 series and new converged storage products use the PCIe Scale-Out architecture.

C.

OceanStor Dorado 18000 uses 200 Gbit/s RDMA shared interface modules for cross-engine expansion, implementing full interconnection between 8, 12, and 16 controllers.

D.

OceanStor Dorado 18000 supports a maximum of 28 interface modules and implements intra-engine mirroring and cross-engine interconnection through the 100 Gbit/s RDMA network.

Question 24

If a performance Issue occurs in Huawei flash storage, an engineer can perform optimization operations according to the storage performance optimization process. Which of the following statements is false about the performance optimization process?

Options:

A.

In the information collection phase, the engineer needs to collect basic information about applications and data, such as the impact of application configurations on data, data size, and read/write ratio.

B.

In the test and application phase, the engineer needs to test the configurations to check whether the optimization objective is achieved. If yes, the engineer can put the system into use.

C.

In the optimization analysis phase, the engineer needs to specify the performance optimization objective, find out the performance bottleneck, and identify the parts that play a key role in Improving the system performance.

D.

In the optimization operation phase, the engineer needs to deploy DR for the service system, and needs to modify multiple configuration at a time during the optimization configuration.

Question 25

A financial customer has purchased multiple Huawei OceanProtect Backup Storage devices for service data backup protection. Which of the following statements are false about the data reduction principle of OceanProtect Backup Storage? choose all that apply

Options:

A.

The backup storage can perform deduplication and compression for LUNs but not for file systems.

B.

In the data reduction process, the system performs backup data preprocessing and then variable-length deduplication.

C.

The backup storage performs feature-based compression for different application data. After compression, the data can be directly written to disks without the need to perform any operations.

D.

In the data reduction process, backup data is divided into blocks of a fixed size based on its content for fixed-length deduplication.

Question 26

An industry customer purchased several Huawei OceanStor Pacific series scale-out storage devices for service deployment, and an engineer configured the SmartMigration feature on the storage devices. Now the engineer wants to change the split mode and migration rate of a SmartMigration task due to changes in service requirements. Which of the following SmartMigration running statuses does not allow the engineer to perform the change?

Options:

A.

Interrupted

B.

Paused

C.

Faulty

D.

Migrating

Question 27

A financial customer purchased an OceanStor Dorado 18000 storage system for basic service deployment. During management, an engineer discovered that the running status of an iSCSI port on DeviceManager was "Link down". After checking the indicator in the equipment room, the engineer discovered that the link indicator of the iSCSI front-end port was steady red. Which of the following are not the possible causes of the exception?

Options:

A.

The optical module type is incompatible with the host port.

B.

The IP address of the iSCSI front-end port is incorrect.

C.

The cable between the application server and the storage device is loose.

D.

The IP address of the service network port on the application server is incorrectly set.

Question 28

Huawei OceanProtect Appliance provides strong data protection capabilities. Which of the following statements is true about the functional architecture of the Appliance?

Options:

A.

ProtectManager is a data flow module that performs data backup, restoration, replication, archive, and copy mounting.

B.

File system management and protocol access are implemented by the data protection layer.

C.

During data protection, the Appliance can protect application data without backup agents.

D.

DataEnable Engine is a data enabling module for global search and data anonymization.

Question 29

In Huawei flash storage, the administrator rote has full control permissions on storage devices. The administrator can power on, power off, and restart devices and create users of different roles.

Options:

A.

TRUE

B.

FALSE

Question 30

Huawei scale-out storage provides file services using the distributed parallel client (DPC) to meet the requirements of high-performance computing (HPC) scenarios. Which of the following statements about the DPC is false?

Options:

A.

DPC provides high storage performance for HPC scenarios.

B.

DPC implements I/O-level load balancing, preventing service load forwarding between storage nodes.

C.

A single client can connect to multiple storage nodes, and the single-stream bandwidth is high.

D.

DPC does not support MPI-I/O. Therefore, DPC can provide better access performance for upper-layer services.

Question 31

A financial customer purchases several Huawel OceanStor Dorado series storage devices for service deployment. During a maintenance process, an engineer needs to use DeviceManager to collect disk health analysis (DHA) logs. Which of the following is not Included in DHA logs?

Options:

A.

I/O statistics

B.

Routine disk health statistics

C.

Device latency statistics

D.

Disk life span information

Question 32

During routine inspection, engineers find that several faults occur on Huawei all-flash storage and need to rectify the faults. Which of the following is not a basic troubleshooting principle for storage systems?

Options:

A.

Analyze network alarms before NE alarms.

B.

Analyze general alarms before specific alarms.

C.

Analyze alarms of higher severities before those of lower severities.

D.

Analyze external factors before internal factors.

Question 33

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Question 34

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

Options:

Question 35

Cache policies and configurations are involved in storage-layer performance optimization of Huawei flash storage. Which of the following statements is false about the high and low watermarks of a cache?

Options:

A.

Generally, the low watermark for storing dirty data in the cache should not be too low. The recommended value is 20%.

B.

Generally, the high watermark of the cache should not be too high, and the difference between the high and low watermarks should not be too small.

C.

If the high watermark of the cache is too high, I/O fluctuation and latency increase will occur usually when the current I/O traffic bursts.

D.

If the high watermark of the cache is too high, the write performance will be affected. If the low watermark of the cache is too low, the read performance will be affected.

Question 36

Assume a financial customer purchased several Huawei scale-out storage devices for deploying the video surveillance service. This service has high requirements on performance. Therefore, the cache write policy must be set to write-through for the storage devices.

Options:

A.

TRUE

B.

FALSE

Question 37

When deploying a Huawei converged storage system, engineer A uses the UltraPath software. Which of the following statements are false about the load balancing algorithms of UltraPath?

Options:

A.

The min-queue-depth algorithm refers to the minimum queue depth algorithm. UltraPath is configured with this algorithm by default.

B.

Round robin is a min-task algorithm and can be used in scenarios where service I/O model data blocks delivered by the host are large.

C.

The min-task algorithm is a round robin algorithm and can be used in scenarios where the service I/O models delivered by the host have little difference.

D.

The algorithms fall into three types: min-queue-depth, round-robin, and min-task.

Page: 1 / 13
Total 125 questions