Question 1

An Industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperReplication feature on the storage devices. During the configuration, the engineer needs to create an authentication user with the role of "Remote device administrator" on the remote device and then add the remote device.

Options:

A.

TRUE

B.

FALSE

Question 2

After a remote replication consistency group is created, if one remote replication task is faulty, other tasks in the consistency group run normally without waiting for the faulty task to recover.

Options:

A.

TRUE

B.

FALSE

Question 3

The performance of a storage system can be measured by multiple indicators. In application scenarios where the I/O size is greater than or equal to 64 KB, the ________ performance indicator is the main concern for storage performance.

Options:

Question 4

A financial customer purchases several Huawel OceanStor Dorado series storage devices for service deployment. During a maintenance process, an engineer needs to use DeviceManager to collect disk health analysis (DHA) logs. Which of the following is not Included in DHA logs?

Options:

A.

I/O statistics

B.

Routine disk health statistics

C.

Device latency statistics

D.

Disk life span information

Question 5

An industry customer has purchased a Huawei OceanStor Pacific scale-out storage system for service deployment. An engineer configures NFS file sharing on the storage system through NFSv4.0. Which of the following commands can the engineer use to switch the user view to the developer view on the command line interface (CLI)?

Options:

A.

change domain ad_manager operation=develop

B.

change dns general address=develop

C.

change user_mode current_mode user_mode=developer

D.

change nas_Idap advanced_config

Question 6

Assume a government customer purchased several Huawei scale-out storage devices for service deployment. An engineer needs to configure file services in standard protocol scenarios. Which of the following actions does not need to be performed by the engineer during the configuration?

Options:

A.

Install DPC.

B.

Create a converged storage pool.

C.

Create namespaces.

D.

Enable the file service for nodes.

Question 7

In Huawei flash storage. If an engineer wants to remotely power on the storage system, the engineer must make an appropriate networking plan for the controller enclosures of the storage system. Which of the following statements is false about the networking principles of a storage system with multiple controller enclosures?

Options:

A.

All power cables have been connected properly to the controller enclosures.

B.

The maintenance network ports of all the controller enclosures have been connected correctly in accordance with standard networking.

C.

All scale-out cables have been connected property to the controller enclosures.

D.

The maintenance terminal has been connected to any service network port on any controller enclosure.

Question 8

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

Options:

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Question 9

Which of the following statements are false about the distributed parallel dlent (DPC) of Huawei scale-out storage products?

Options:

A.

If you want to reserve resources for deploying DPC, the available memory of compute nodes must be greater than or equal to 8 GB, and the memory reserved for the operating system must be greater than or equal to 4 GB.

B.

To enable the performance mode of CPUs, you can run the "cpupower frequency-set -g performance" command.

C.

If services running on DPC require higher performance, you can set CPUs to work in performance mode.

D.

DPC and non-uniform memory access (NUMA) are mutually exclusive. Therefore, the NUMA affinity tuning feature cannot be provided in actual scenarios.

Question 10

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Question 11

In Huawei container storage solution, CSI is short for Container Storage Interface. Which of the following statements is false about Huawei CSI?

Options:

A.

CSI Driver developed by Huawei is mainly used to implement the call initiated by sidecar on Huawei storage.

B.

Huawei storage and Huawei CSI driver need to communicate with each other through RESTful to provide NAS/SAN storage resources.

C.

CSI Controller runs independently on a worker node on the Pod in StatefulSet mode and is used to interact with the storage and create and delete resources on the storage side.

D.

CSI Node runs on each worker node of Kubernetes on the Pod in DaemonSet mode and can be used to mount and unmount related storage resources.

Question 12

After purchasing a Huawei OceanStor Dorado series storage system, a customer needs to configure basic storage services in the storage system. Which of the following operations are optional in the basic service configuration?

Options:

A.

Configuring connectivity between a host and the storage system

B.

Creating a port group

C.

Creating a mapping

D.

Creating a LUN group

Question 13

For device reliability purposes, during the quick Installation of OceanStor Pacific 9550, engineers need to connect power cables on the storage device supplied by two power modules to separate power distribution units (PDUs).

Options:

A.

TRUE

B.

FALSE

Question 14

The LUN active-active balancing feature of Huawei all flash storage Integrates the global load balancing.design. The front-end interface board evenly distributes I/Os to the target controller for load balancing.

Options:

Question 15

The service system needs to be backed up before performance optimization b performed on Huawei flash storage, and up to two optimization configurations can be changed at a time.

Options:

A.

TRUE

B.

FALSE

Question 16

Huawel OceanStor Pacific series storage supports the volume- or snapshot-based clone feature. Which of the following statements Is false about this feature?

Options:

A.

Small storage space occupation: A clone generated by the storage system is not a full physical data copy, which does not occupy large storage space.

B.

Quick generation: The storage system can generate a clone within several seconds to obtain the consistent copy of the source volume data.

C.

Lossless performance: Based on the ROW mechanism, the done write performance is equivalent to the source volume write performance.

D.

Cascading: Clones can be created based on clone volumes or snapshots of clone volumes in the storage system. A maximum of 64 cascading levels are supported.

Question 17

A financial customer purchases a Huawei flash storage device for subsequent service deployment. During storage configuration, an administrator finds that LUNs mapped to an application server cannot be detected on the application server. Which of the following are possible causes of this exception?

Options:

A.

The storage pool is faulty.

B.

In HP-UX, the application server does not have a LUN mapping whose host LUN ID is 0.

C.

In UNIX or Linux, a device node file is lost.

D.

The serial port connection parameters are incorrectly set.

Question 18

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Question 19

When delivering a flash storage project, Huawei engineers introduced the arbitration mechanism of HyperMetro to the customer. Which of the following statements is false about the arbitration modes?

Options:

A.

If no quorum server is configured, HyperMetro works in static priority mode. When an arbitration occurs, the preferred site wins the arbitration and provides services.

B.

In static priority mode, if the preferred site of a HyperMetro pair breaks down, the non-preferred site does not automatically take over HyperMetro services. As a result, the services stop, and the customer must forcibly start the services at the non-preferred site.

C.

In quorum server mode, the quorum server can be deployed only on physical machines and not on virtual machines.

D.

In quorum server mode, if the link between storage systems is down, each storage system sends an arbitration request to the quorum server.

Question 20

Assume an industry customer purchased several Huawei flash storage devices for service deployment. During routine management, an engineer found that the host bus adapter (HBA) driver version of the host is outdated and the number of concurrent HBAs was insufficient. As a result, the latency on the host differs greatly from that on the storage side. Which of the following measures can the engineer take to optimize performance?

Options:

A.

Use the management software provided by the HBA vendor to query and modify the number of concurrent HBAs.

B.

Upgrade the HBA driver to the latest version.

C.

Change the load balancing algorithm of the multipathing software to min-task.

D.

Change the cache prefetch policy to constant prefetch.

Question 21

Huawel OceanStor Pacific series products provide object storage capabilities and support cross-site disaster recovery (DR). Which of the following statements about object storage cross-site DR is false?

Options:

A.

In cross-site DR cluster deployment mode, each site is independent. Specifically, it has an independent DeviceManager GUI and independent erasure code (EC) configuration.

B.

In backup and archiving scenarios that do not require a low latency, the redundancy mode between sites can be set to EC redundancy during cross site DR configuration.

C.

During cross-site DR configuration, if replicas are used for redundancy protection across sites, each site has complete object data.

D.

The cross-site DR of OceanStor Pacific series uses an asynchronous replication mechanism. The recovery point objective (RPO) is greater than 0, and the traffic control configuration cannot be adjusted.

Question 22

In Huawei all flash storage, the_____feature can automatically store data in different locations based on specified rules for intelligent data management.

Options:

Question 23

When delivering a Huawel OceanStor Pacific scale-out storage project, an engineer introduced the end-to-end data Integrity check technology of scale-out storage to the customer. Which of the following statements are false about this technology?

Options:

A.

This technology enables the storage system to implement periodic background data integrity check. When the service load is heavy or service access is frequent, the system automatically starts periodic background data integrity check and self-healing.

B.

For silent data scenarios such as bit change and read offset, the end-to-end data integrity check technology supports logical block addressing (LBA) check of clusters and hosts.

C.

Block, NAS, and object services support end-to-end data integrity check, but the HDF5 service does not.

D.

In this technology, write requests are checked at the system entry (virtual block service). User data is checked again in the object storage device (OSD) before being written to disks. Data Is written to disks only after the data integrity check succeeds.

Question 24

Huawei OceanStor Pacific series is an intelligent scale-out storage product that supports large-scale scale-out and delivers high reliability. Which of the following statements are false about the product’s reliability?

Options:

A.

In terms of data reliability, multiple RAID policies are supported based on the traditional disk-level RAID mode.

B.

The product adopts Kunpeng processors to integrate functions of multiple chips and effectively improve hardware reliability.

C.

The product leverages link aggregation to ensure transmission link redundancy and performs link switchover or isolation to ensure service continuity if a link becomes faulty or subhealthy.

D.

The product uses the multi-copy technology to implement the intra-node RAID function. If a node is faulty, the system reliability is not degraded and even remains higher than that of the EC mechanism.

Question 25

A financial customer purchases a Huawei OceanStor Pacific 9950 storage device for service deployment. Engineers have configured basic block storage services on the device. During an O&M management process, an engineer needs to modify the attributes of a storage pool. Which of the following attributes will not be modified?

Options:

A.

Hot spare policy of the storage pool

B.

Storage pool name

C.

Actual location of the storage pool

D.

Capacity alarm threshold

Question 26

A faulty storage hardware module needs to be replaced. Which of the following components can be replaced online?

Options:

A.

Controller enclosure backplane

B.

BBU

C.

Disk

D.

Interface module

Question 27

An Industry customer purchases several Huawei flash storage devices for service deployment. During an inspection, an engineer finds that some storage components are faulty and need to be removed and replaced. Which of the following statements Is true about the part removal and replacement?

Options:

A.

The interface modules and system subracks of the storage device can be replaced independently.

B.

The CPUs of the storage device cannot be replaced independently, but can be removed independently.

C.

The memory modules and system disks of the storage device can be removed and replaced independently.

D.

The coin batteries of the storage device cannot be replaced or removed.

Question 28

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Question 29

Before configuring services for Huawei flash storage, you need to Initialize the system. Which statement about the initialization is false?

Options:

A.

You must change the IP addresses of the management network port and maintenance network port using the command-line interface (CLt) before applying for and activating a license.

B.

During security configuration management, read-only users have only the access permission to the storage device, that is, they can only perform query operations.

C.

When the TCP+SSl/TLS protocols are used for Syslog alarm notification, you need to set the certificate verification mode to improve the security of storage system logs.

D.

During the wizard-based initialization, you need to configure basic information, such as device information, device time, and licenses.

Question 30

If Huawei scale-out storage software is installed in low level design (LLD) mode, engineers need to use the ________ installation and deployment tool to plan nodes, networks, and clusters and export the configuration file for subsequent installation and deployment.

Options:

Question 31

In Huawei flash storage. If you want to apply the HyperCDP feature to a LUN, you are advised to reserve 5% to 10% of the LUN capacity in the storage pool to which the I UN belongs for storing HyperCDP object data, and configure a protection capacity threshold for the storage pool to stop creating HyperCDP objects or even automatically delete HyperCDP objects when the storage pool capacity is insufficient.

Options:

A.

TRUE

B.

FALSE

Page: 1 / 11