Water Damage Restoration Technician (WRT) Questions and Answers
Which term describes the rate of water vapor passing through a material?
Options:
Capillarity
Permeance
Condensation
Wicking
Answer:
BExplanation:
The IICRC WRT body of knowledge definespermeanceas the rate at which water vapor passes through a material. It is a measure of a material’s vapor transmission characteristics and plays a significant role in drying dynamics and moisture management.
Materials with high permeance allow water vapor to pass through easily, supporting evaporation and drying. Low-permeance materials act as vapor retarders or barriers, restricting vapor movement and potentially trapping moisture within assemblies.
The WRT manual emphasizes evaluating material permeance when selecting drying methods. For example, vinyl wall coverings or certain flooring systems impede vapor movement, often requiring disruptive drying techniques.
Capillarity and wicking describe liquid moisture movement, while condensation is a phase change process. Only permeance directly describes vapor transmission through materials, making it the correct term under WRT science.
Which of the following regulated hazardous materials require compliance with federal and local laws and regulations to remove or repair?
Options:
Vinyl composition tile and luxury vinyl tile
Acoustical tiles and gypsum board
Lead-based paint and asbestos-containing adhesive
Hardboard and medium-density fiberboard
Answer:
CExplanation:
The IICRC WRT body of knowledge explicitly recognizes lead-based paint and asbestos-containing materials as regulated hazardous materials that require compliance with federal, state, and local laws when disturbed, removed, or repaired. These materials pose significant health risks when fibers or particles become airborne and are therefore subject to strict regulatory oversight.
Lead-based paint, commonly found in structures built before regulatory bans, can produce hazardous dust during demolition or sanding. Asbestos-containing adhesives, mastics, or building materials can release microscopic fibers when disturbed, leading to long-term respiratory disease risks. The WRT manual emphasizes that restoration technicians must not disturb regulated materials unless they are properly trained, certified, and authorized to do so, or unless licensed specialists are retained.
The presence of regulated materials must be identified during the initial inspection and hazard assessment, and work plans must be adjusted accordingly. Failure to comply with applicable regulations can result in serious legal liability, fines, and health consequences.
Other listed materials—such as gypsum board, MDF, or vinyl flooring—may require removal due to water damage but are not inherently regulated hazardous materials under federal law. The WRT standard reinforces that compliance with environmental and occupational safety regulations is a non-negotiable component of professional restoration practice.
What do moisture detection instruments allow a restorer to evaluate and document?
Options:
Count particulates of aerosolized contaminants
Manometer readings for the purpose of drying
Thermographic readings and images from a thermal camera
Psychrometric conditions and moisture content or level readings
Answer:
DExplanation:
The IICRC WRT body of knowledge states that moisture detection instruments allow restorers to evaluate and documentpsychrometric conditions and moisture content or moisture level readings. These measurements form the foundation of drying verification and defensible documentation.
Moisture meters measure moisture within materials, while thermo-hygrometers capture air temperature and relative humidity, enabling calculation of dew point, humidity ratio, and vapor pressure. Together, these tools allow restorers to assess drying effectiveness, establish drying goals, and demonstrate progress over time.
Thermal imaging provides indirect information and must be verified, while manometers and particulate counters serve specialized purposes outside routine moisture documentation.
The WRT manual emphasizes consistent measurement, proper instrument selection, and clear documentation as essential components of professional restoration practice and project closeout.
Which class of water intrusion is it where the affected materials represent approximately 5% to 40% of the combined surface area in the space and where materials described as low-evaporation materials or assemblies have absorbed minimal moisture?
Options:
Class 1
Class 2
Class 3
Class 4
Answer:
BExplanation:
The IICRC WRT body of knowledge definesClass 2 water intrusionas a condition where asignificant portion of a room (approximately 5% to 40% of combined surface area)is affected, and where moisture has wicked into structural materials such as carpet, cushion, and drywall, but absorption remains relatively shallow.
Class 2 losses typically involve wet carpet and cushion with minimal wall saturation. Evaporation rates are higher than Class 1 but do not reach the extensive saturation levels of Class 3. Low-evaporation materials may be affected, but moisture penetration remains limited.
The WRT manual uses this classification to guide equipment selection, drying strategy, and time expectations. Class 1 involves minimal absorption, Class 3 involves extensive saturation of ceilings, walls, and insulation, and Class 4 involves deeply bound water.
Accurate classification during initial inspection is essential for defensible restoration planning under the IICRC standard of care.
What is the atmospheric condition with the lowest humidity ratio?
Options:
40°F (4°C) and 80% RH
70°F (21°C) and 80% RH
80°F (27°C) and 60% RH
90°F (32°C) and 30% RH
Answer:
AExplanation:
The IICRC WRT body of knowledge teaches thathumidity ratiorepresents the actual mass of water vapor contained in air and is independent of relative humidity alone. To determine which condition has the lowest humidity ratio, both temperature and relative humidity must be considered together using psychrometric principles.
Cool air holds significantly less moisture than warm air, even at higher relative humidity percentages. At40°F and 80% RH, the air contains very little moisture compared to warmer air at lower RH values. In contrast, warmer air—even at 30–60% RH—typically contains more total moisture due to its greater vapor-holding capacity.
The WRT manual emphasizes that relying solely on relative humidity is misleading. Psychrometric evaluation is required when comparing air conditions for ventilation drying. Among the listed options, 40°F and 80% RH has the lowest humidity ratio and therefore the driest air in terms of moisture content.
This principle reinforces why cold outdoor air can sometimes be effective for ventilation drying, provided condensation risks are managed.
What happens when the surface temperature of a material is at or below the dew point temperature of the air?
Options:
Dehumidification
Evaporation
Sublimation
Condensation
Answer:
DExplanation:
According to the IICRC WRT body of knowledge,condensationoccurs when the surface temperature of a material is at or below the dew point temperature of the surrounding air. Under these conditions, the air can no longer hold all of its water vapor, and moisture changes phase from vapor to liquid on the cooler surface.
This principle is fundamental to psychrometry and is directly applicable to water damage restoration. The WRT manual emphasizes that condensation represents amoisture gain, not moisture removal, and therefore counteracts drying efforts. When condensation occurs on structural materials, it can increase moisture content, prolong drying time, and contribute to secondary damage such as microbial growth or corrosion.
Restorers are trained to compare indoor air dew point measurements with surface temperatures of materials using thermo-hygrometers and infrared thermometers. If surface temperatures are below the dew point, corrective action—such as increasing temperature, improving dehumidification, or adjusting airflow—is required.
This concept also explains why cold surfaces like metal framing, concrete, or supply ductwork can develop moisture even without direct water exposure. The WRT curriculum stresses proactive monitoring to prevent unintended condensation events during drying.
In order to increase the rate of evaporation, what should the surface temperature of the material be?
Options:
Below dew point temperature
Above relative humidity
Equal to vapor pressure
Above dew point temperature
Answer:
DExplanation:
The IICRC WRT body of knowledge explains that to increase therate of evaporation, the surface temperature of wet materials must beabove the dew point temperatureof the surrounding air. When a surface is warmer than the dew point, water molecules have sufficient energy to change from a liquid state to a vapor state and move into the air.
If a surface temperature falls at or below the dew point, condensation occurs instead of evaporation, adding moisture back onto the material. This condition directly opposes drying and can result in secondary damage. The WRT curriculum therefore emphasizes continuous monitoring of both air dew point and material surface temperatures to ensure evaporation conditions are maintained.
Relative humidity is not a temperature, and vapor pressure equality does not drive evaporation. Only maintaining surface temperatures above dew point ensures positive evaporation potential.
This principle is fundamental to restorative drying and is repeatedly reinforced throughout WRT psychrometric training.
In order to effectively dry subflooring installed below sheet vinyl flooring, what should a restorer typically do?
Options:
Leave extra drying equipment
Remove and discard the vinyl
Perforate and dry the vinyl surface
Place an air mover under one corner
Answer:
BExplanation:
The IICRC WRT body of knowledge explains thatsheet vinyl flooring acts as a vapor barrier, significantly restricting moisture vapor movement from the subfloor beneath it. Because evaporation is inhibited, subflooring beneath vinyl cannot be effectively dried while the covering remains intact.
As a result, the WRT manual states that the most effective and reliable method is toremove and discard the vinyl flooringto allow direct access for drying. This enables airflow, temperature control, and dehumidification to act directly on the wet subfloor.
Perforating vinyl is unreliable and may cause additional damage without ensuring adequate vapor release. Placing an air mover at an edge does not overcome the vapor barrier effect. Simply adding equipment without removing the barrier does not resolve the drying limitation.
Removing vinyl aligns with the WRT principle that vapor barriers must be addressed to achieve effective drying and prevent hidden moisture from causing secondary damage.
Which of the following is a benefit of a low-grain refrigerant (LGR) dehumidifier?
Options:
It operates down to 0°F (–17°C)
It can operate efficiently above 110°F
It reduces vapor pressure lower than a desiccant dehumidifier
It reduces vapor pressure lower than a conventional dehumidifier
Answer:
DExplanation:
The IICRC WRT body of knowledge explains thatlow-grain refrigerant (LGR) dehumidifiersare designed to remove moisture more efficiently at lower humidity ratios than conventional refrigerant dehumidifiers. As a result, LGR units can reduceair vapor pressure to lower levelsthan standard refrigerant systems under similar conditions.
This enhanced capability allows LGR dehumidifiers to continue removing moisture even as the environment becomes drier, supporting faster and more complete drying. The WRT manual highlights this feature as a key advantage of LGR technology in most residential and light commercial drying scenarios.
LGR units do not operate effectively at freezing temperatures, are not optimized for extreme heat, and cannot achieve vapor pressure levels lower than desiccant systems. Desiccants remain superior for very low humidity or low-temperature conditions.
Therefore, the correct benefit under WRT guidance is the ability of LGR dehumidifiers to reduce vapor pressure lower than conventional refrigerant dehumidifiers.
If the ambient temperature is below 50°F, what is the most effective type of dehumidifier to use when drying a structure?
Options:
Gas bypass dehumidifier
Low-grain refrigerant dehumidifier
Conventional dehumidifier
Desiccant dehumidifier
Answer:
DExplanation:
The IICRC WRT body of knowledge states thatdesiccant dehumidifiersare the most effective option when ambient temperatures fall below approximately50°F. Refrigerant-based dehumidifiers rely on condensation at cold coils and become inefficient or inoperative at lower temperatures due to coil icing and reduced moisture removal capacity.
Desiccant systems remove moisture throughadsorption, a chemical bonding process that is not dependent on air temperature. This allows desiccants to perform effectively in cold environments where refrigerant units fail.
The WRT manual highlights desiccants as the preferred solution for cold structures, unheated buildings, winter losses, and Class 4 drying scenarios. Gas bypass and LGR units extend the operating range of refrigerants but still have temperature limitations.
Selecting the correct dehumidifier type based on ambient conditions is a core competency under the WRT standard and ensures efficient, defensible drying.
Where should a restorer inspect in a water-damaged structure?
Options:
Areas where odors exist
Locations where water is visible
Rooms the customer says were affected
All potentially affected areas
Answer:
DExplanation:
The IICRC WRT body of knowledge clearly states that a restorer must inspectall potentially affected areasin a water-damaged structure. Water migration is often hidden and does not always follow visible or obvious paths. Gravity, capillary action, air movement, and building assemblies can allow water to spread far beyond the area initially identified by occupants.
The WRT manual emphasizes that relying solely on visible water, odors, or customer statements is insufficient and can result in missed moisture, incomplete drying, and secondary damage. Hidden moisture may exist behind walls, under flooring, inside cabinets, beneath insulation, or in adjacent rooms not immediately associated with the loss.
A comprehensive inspection includes visual assessment, moisture detection instruments, infrared imaging (verified with meters), and evaluation of building construction features that may facilitate water movement. This approach ensures accurate scoping, proper classification, and effective drying system design.
Inspecting all potentially affected areas aligns with the ANSI/IICRC S500 Standard’s requirement for thorough evaluation and defensible documentation, reducing the risk of undiscovered moisture and future claims.
As the air temperature increases and no additional moisture is added to the air, what happens to relative humidity?
Options:
It reaches the dew point
It decreases
It remains the same
It increases
Answer:
BExplanation:
The IICRC WRT body of knowledge explains thatrelative humidity decreaseswhen air temperature increases and no additional moisture is added. This occurs because warmer air can hold more water vapor; therefore, the same amount of moisture represents a smaller percentage of the air’s total capacity.
This principle is foundational in psychrometry and directly applied in restoration drying. By increasing temperature while controlling moisture content, restorers lower relative humidity and vapor pressure, increasing evaporation potential.
Relative humidity does not remain constant with temperature changes, nor does it increase unless moisture is added. Dew point remains unchanged unless moisture content changes.
Understanding this relationship allows restorers to use controlled heat strategically to improve drying efficiency without introducing excess moisture.
How shall a technician use government-registered antimicrobials (biocides)?
Options:
Estimate the proper dilution
Combine with an acidic cleaner
Follow the label directions
Dilute the product to increase the effect
Answer:
CExplanation:
The IICRC WRT body of knowledge mandates that EPA-registered antimicrobials (biocides) must be used strictly in accordance with the product label directions. Under U.S. law, the label is considered a legal document, and deviation from label instructions constitutes misuse of a pesticide.
Label directions specify approved application methods, dilution ratios, dwell times, PPE requirements, ventilation needs, and occupant restrictions. The WRT manual emphasizes that technicians are not permitted to alter concentrations, combine products, or improvise application techniques, regardless of perceived effectiveness.
Estimating dilution or increasing concentration does not improve efficacy and may create safety hazards, damage materials, or expose occupants and workers to chemical risks. Combining products can produce toxic reactions, while under-dilution or over-dilution may render the antimicrobial ineffective or unsafe.
The WRT curriculum reinforces that antimicrobials are supplemental tools, not replacements for removal of unsalvageable materials or proper drying. Proper use ensures regulatory compliance, protects health, and limits liability for the restorer.
When should carpet cushion (pad, underlay) be removed and discarded?
Options:
If it is affected with Category 2 or Category 3 water
If it is installed over plywood subflooring
If it has a porous membrane or “skin”
If it is a synthetic felt cushion
Answer:
AExplanation:
The IICRC WRT body of knowledge states thatcarpet cushion (pad, underlay) must be removed and discarded when affected by Category 2 or Category 3 water. Carpet cushion is a porous material that readily absorbs and retains contaminants, making effective cleaning and decontamination impractical under these conditions.
The WRT manual explains that even if the overlying carpet may be cleanable in some situations, cushion acts like a sponge and can harbor microorganisms, nutrients, and moisture deep within its structure. Attempting to dry or disinfect contaminated cushion poses a health risk and increases the likelihood of secondary damage or odor problems.
While certain cushion types (such as synthetic felt or cushions with skins) influence restorability in Category 1 losses, contamination level takes precedence. The presence of Category 2 or 3 water alone is sufficient to require removal, regardless of cushion construction or subfloor type.
This guidance reflects the WRT emphasis on protecting occupant health and preventing hidden contamination. Removing and discarding contaminated cushion is considered the appropriate and defensible standard of care.
What is a likely outcome when the vapor pressure in a drying chamber is lower than the vapor pressure of the wet materials?
Options:
The category of water may degrade
Moisture can move from the air into the materials
The class of intrusion will increase
Moisture can move from the materials into the air
Answer:
DExplanation:
The IICRC WRT body of knowledge explains that moisture movement is governed byvapor pressure differentials. When the vapor pressure within wet materials is higher than the vapor pressure of the surrounding air, moisture naturally migrates from the materials into the air. This condition is essential for effective drying.
A drying chamber with lower vapor pressure than the wet materials creates the necessary driving force for evaporation. The WRT manual emphasizes that this differential is achieved by reducing humidity ratio through dehumidification and increasing temperature and airflow at the material surface.
If the opposite condition exists—where air vapor pressure is higher than material vapor pressure—moisture can migrate into materials, causing secondary wetting. Therefore, maintaining lower vapor pressure in the air than in the materials is a core objective of restoration drying systems.
The class or category of water does not change due to vapor pressure alone; those are classification concepts based on absorption and contamination. The correct outcome under WRT science is moisture migration from materials into the air.
What steps should be taken to minimize safety concerns with sagging gypsum board ceilings and promote rapid drying?
Options:
Drain, safely remove, and properly dispose
Perforate to increase airflow while drying
Drain, properly dry the gypsum, and reinstall
Support to prevent collapse while drying
Answer:
AExplanation:
The IICRC WRT body of knowledge identifiessagging gypsum board ceilingsas a seriousstructural and safety hazard. Gypsum board loses strength when wet, especially in horizontal installations, and sagging indicates primary damage that cannot be safely reversed.
The WRT manual clearly states that wet gypsum ceilings presenting sagging or collapse risk must bedrained, safely removed, and properly disposed of. Attempting to dry sagging ceiling drywall in place is unsafe and inconsistent with professional standards.
Perforation or temporary support does not restore structural integrity and exposes workers and occupants to collapse hazards. Reinstallation is only appropriate after damaged materials are removed and the structure is dried.
This guidance reinforces the WRT principle thatlife safety always overrides salvage considerations. Removing compromised ceiling drywall eliminates hazards and allows drying equipment to operate more effectively on remaining structural components.
What percentage of relative humidity has the greatest potential for structural or microbial damage to hygroscopic materials to occur?
Options:
30%
40%
50%
70%
Answer:
DExplanation:
The IICRC WRT body of knowledge identifiesrelative humidity at or above approximately 70%as presenting the greatest risk for structural and microbial damage to hygroscopic materials. At this level, many materials readily absorb moisture from the air, increasing moisture content even without direct liquid water contact.
The WRT manual explains that hygroscopic materials such as wood, paper, drywall, and textiles reach higher equilibrium moisture contents as RH increases. When RH exceeds safe thresholds, these materials may swell, deform, lose structural integrity, or support microbial growth.
Microbial amplification risk also increases significantly at higher RH levels. While mold growth depends on multiple factors, sustained RH above approximately 60–70% greatly increases the likelihood of microbial activity on organic materials.
This is why restorers are trained to aggressively control humidity during drying and to monitor RH as part of daily documentation. Maintaining RH well below damaging thresholds protects unaffected materials and limits secondary damage during the restoration process.
Which drying system creates the lowest vapor pressure?
Options:
A heat drying system
An inter-air drying system
A system with an LGR dehumidifier
A system with a desiccant dehumidifier
Answer:
DExplanation:
The IICRC WRT body of knowledge identifiesdesiccant dehumidification systemsas capable of creating thelowest vapor pressurein a drying environment. Desiccant systems remove moisture through adsorption, allowing them to achieve extremely low humidity ratios and vapor pressures—lower than refrigerant-based systems can typically reach.
Because vapor pressure drives moisture movement, achieving very low air vapor pressure significantly increases the drying potential for dense or low-permeance materials. This is why desiccant systems are often specified for Class 4 drying, cold environments, or situations requiring aggressive moisture removal.
Heat-only systems increase vapor pressure unless paired with moisture removal. Inter-air systems enhance airflow but do not independently reduce vapor pressure. LGR dehumidifiers reduce vapor pressure effectively but not to the same extent as desiccants.
The WRT curriculum emphasizes that system selection must be based on drying objectives and material characteristics, with desiccants reserved for scenarios requiring maximum vapor pressure reduction.
Which material loses most of its structural integrity when wet but regains its strength when dry?
Options:
Concrete
Gypsum board (drywall)
Plywood
Hardwood flooring
Answer:
BExplanation:
Gypsum board (drywall) is identified in the WRT body of knowledge as highly vulnerable to moisture exposure, yet capable of recovering strength when dried—provided it has not sustained irreversible primary damage. The WRT manual explains that gypsum wallboard is among the most moisture-sensitive common building materials, showing rapid and dramatic change with elevated moisture levels. However, it also states that gypsum has a greater ability to recover than many other engineered products.
Critically, the WRT guidance distinguishes between primary damage (immediate structural failure) and recoverable wetting. For example, overhead or horizontally installed gypsum that becomes wet can lose structural integrity, sag, and create a significant safety concern; this sagging is considered permanent damage and requires removal.
In contrast, when gypsum board installed vertically on walls is wet but has not experienced primary damage (e.g., not structurally compromised, not severely deteriorated, and appropriate contamination considerations are addressed), the WRT manual notes that it can restore: during the drying process, gypsum’s original strength is restored, and after drying it may even be slightly stronger (though sometimes more brittle). This recovery characteristic is what makes gypsum board the best match to the question’s description—losing structural integrity when wet yet regaining strength when properly dried.
This material behavior is central to WRT decision-making: whether to dry in place, perform limited disruption (e.g., baseboard removal and cavity airflow), or remove materials for safety/health reasons. The WRT body of knowledge treats gypsum as potentially restorable depending on installation orientation, degree of damage, and contamination risk, which is why it is specifically described as losing integrity when wet and regaining strength when dry.
==========
Which best describes Category 2 water?
Options:
Water that originates from a sanitary source and flows into an uncontaminated building
Water that contains significant contamination and has the potential to cause discomfort or sickness if contacted or consumed by humans
Water that originates from a sanitary water source and does not pose substantial risk from ingestion or inhalation exposure
Water that is grossly contaminated and can contain pathogenic, toxigenic, or other harmful agents
Answer:
BExplanation:
The IICRC WRT body of knowledge definesCategory 2 wateras water that contains significant contamination and has the potential to cause discomfort or illness if contacted or consumed. This classification recognizes that while Category 2 water is not grossly contaminated like Category 3, it is no longer considered clean or sanitary.
Examples commonly cited in the WRT manual include dishwasher or washing machine discharge, toilet overflows with urine but no feces, and seepage due to hydrostatic pressure. These sources may contain microorganisms, nutrients for microbial growth, or other contaminants that pose health concerns.
The WRT standard emphasizes that Category 2 water presents anelevated health riskand requires enhanced controls compared to Category 1. This may include increased PPE, more aggressive cleaning, and careful evaluation of materials for restorability. Porous materials affected by Category 2 water may need to be removed depending on exposure time and degree of absorption.
Importantly, the WRT body of knowledge highlights that water candegrade in categoryover time if left untreated. Category 2 water can become Category 3 due to microbial amplification, reinforcing the importance of timely mitigation and proper classification during the initial inspection.
In order to maximize electrical safety, what shall mitigation equipment include?
Options:
Rubber feet to insulate mechanical components
Water-resistant motor windings
A grounded electrical plug
HEPA filters to trap contaminants
Answer:
CExplanation:
The IICRC WRT body of knowledge emphasizes that mitigation equipment used in wet environments must meetelectrical safety requirements, including the use ofgrounded electrical plugs. Grounding provides a safe path for electrical current in the event of a fault, significantly reducing the risk of shock or electrocution.
Water damage restoration environments frequently involve elevated moisture, standing water, and conductive surfaces, all of which increase electrical hazards. The WRT manual reinforces that grounded plugs and properly rated extension cords are essential safety features for air movers, dehumidifiers, and other electrical equipment.
While water-resistant components and insulating features may enhance durability, they do not replace grounding requirements. HEPA filters address air quality, not electrical safety.
Ensuring grounded equipment aligns with OSHA electrical safety standards and reflects the WRT priority of hazard mitigation before and during restoration work.
Which is typically a result of introducing warm, dry air movement into wall cavities?
Options:
Decreased rate of evaporation
Negative pressure within the chamber wall
Decreased temperature within the chamber
Increased rate of evaporation
Answer:
DExplanation:
The IICRC WRT body of knowledge explains that introducingwarm, dry air movement into wall cavitiestypically results in anincreased rate of evaporation. Warm air raises the temperature of wet materials, increasing vapor pressure within those materials, while dry air lowers ambient vapor pressure—together creating a strong vapor pressure differential.
This differential accelerates moisture movement from materials into the air. The WRT manual notes that cavity drying systems, including inter-air drying, are designed to deliver controlled airflow and low-humidity air directly to concealed wet surfaces, where natural evaporation would otherwise be limited.
Negative pressure may occur in certain containment setups, but it is not the primary outcome of warm, dry airflow into cavities. Temperature reduction contradicts the drying mechanism, and decreased evaporation would indicate system failure rather than expected performance.
The WRT curriculum emphasizes that controlled cavity airflow is an effective technique when materials are restorable and contamination conditions allow, reinforcing evaporation as the intended result.
What is the term for the temperature at which air reaches 100% relative humidity?
Options:
Humidity ratio temperature
Absolute temperature
Dew point temperature
Relative humidity temperature
Answer:
CExplanation:
Dew point temperature is the temperature at which an air mass becomes saturated (100% RH) and can hold no more water vapor. In WRT psychrometry, this is a critical “threshold” condition because any additional cooling of the air (at the same moisture content) forces water vapor to change state and condense onto cooler surfaces. The WRT body of knowledge emphasizes that as air is cooled, its capacity to hold water vapor decreases until RH reaches 100%, which is the dew point condition.
In water damage restoration, dew point is used operationally to manage secondary damage risk and to confirm drying potential. The WRT reference explains that restorers compare the dew point of the indoor air (often the most humid air mass in the structure) to material surface temperatures throughout the affected environment. If a surface temperature is below the dew point, condensation will occur on that surface, potentially increasing moisture loading and causing secondary damage. Conversely, when surface temperatures are warmer than the dew point of the surrounding air, evaporation potential increases, supporting restorative drying.
Because dew point is directly related to humidity ratio and vapor pressure, it also functions as a practical indicator of “how wet the air really is” regardless of temperature changes. This is why dew point is repeatedly referenced alongside vapor pressure and humidity ratio as a foundational psychrometric measurement used to evaluate drying systems and to prevent condensation events during mitigation.
==========
In addition to controlling humidity, what else should a restorer manage to increase the rate of drying?
Options:
Surface temperatures of affected materials
Outside temperatures of building envelopes
Dehumidifier dew point temperatures
Number of occupants in the building
Answer:
AExplanation:
The IICRC WRT body of knowledge identifiessurface temperature of affected materialsas a critical variable influencing the rate of evaporation. Evaporation increases as surface temperature rises, provided the surrounding air has a lower vapor pressure than the material.
The WRT manual explains that increasing surface temperature raises vapor pressure within wet materials, enhancing the vapor pressure differential that drives moisture into the air. This is why controlled heat, airflow, and dehumidification must be managed together.
While outdoor temperatures and dehumidifier coil temperatures may affect system performance, they are indirect factors. Occupant count is not relevant to evaporation physics.
Restorers are trained to monitor material surface temperatures using infrared thermometers and to adjust drying systems accordingly. Managing surface temperature—without exceeding safe limits—supports faster, more efficient drying and reduces overall restoration time.
Who should a technician get documented authorization from before applying an antimicrobial (biocide)?
Options:
The primary adjuster
The owner or occupant
The reconstruction contractor
The primary physician
Answer:
BExplanation:
The IICRC WRT body of knowledge clearly states that before applying an antimicrobial (biocide), a technician must obtaindocumented authorization from the owner or occupant, or another legally authorized representative of the property. This requirement exists because antimicrobial application involves introducing regulated chemical agents into an occupied environment, which carries potential health, legal, and liability implications.
The WRT manual emphasizes informed consent as a professional and ethical obligation. Owners or occupants must be made aware of the purpose, limitations, and potential risks associated with antimicrobial use. Documented authorization protects all materially interested parties by confirming that the decision to apply a biocide was disclosed, understood, and approved.
Insurance adjusters do not have authority over health decisions within a structure, reconstruction contractors do not represent occupancy interests, and physicians are not responsible for property treatment approvals. The responsibility lies with the property owner or occupant.
This requirement aligns with EPA pesticide regulations and the ANSI/IICRC S500 Standard, reinforcing transparency, safety, and defensibility in restoration practices.