Commercial Mechanical Inspector Questions and Answers

Question 1

Ducts shall not be permitted to be connected to:

Options:

A.

an evaporative cooler.

B.

a vented wall furnace.

C.

a gravity-type warm-air furnace.

D.

a high-static-pressure-type unit heater.

Question 2

An equipment shutoff valve shall be in the same room and not more than how many feet away from the appliance?

Options:

A.

6

B.

7

C.

8

D.

9

Question 3

Why are two or more sets of construction documents, engineering calculations, diagrams, and other data required to be submitted with each application for a permit?

Options:

A.

To ensure that the project is completed in a timely manner.

B.

All sets are to be retained by the code official in order to have a spare set of construction documents for use by any subcontractors.

C.

All sets of documents are to be kept by the code official, and at least one set will serve as a backup set of documents in case the other is lost or misplaced.

D.

One set will be retained by the code official, and the other will be returned to the applicant and kept on the job site for reference while construction is in progress.

Question 4

Exhaust outlets that terminate at a temperature exceeding 600°F shall be designed as a:

Options:

A.

Class I duct.

B.

Class II duct.

C.

Class III duct.

D.

single-wall metal chimney.

Question 5

Given: An industrial water heater boiler has a manufacturer’s listing of 18 inches wall clearance. It is installed with a protective wall assembly of 24-gauge sheet metal spaced out 1 inch from the wall.

The reduced installation clearance from the wall for this appliance is _____ inches.

Options:

A.

[option text not fully visible in the material you sent]

B.

[option text not fully visible in the material you sent]

C.

12

D.

18

Question 6

For gas piping installations, which of the following is an acceptable joining method for polyethylene (PE) pipe?

Options:

A.

Rubber cement

B.

Solvent cement

C.

Threaded coupling

D.

Compression coupling

Question 7

When testing dampers located in corridors, the dampers shall demonstrate acceptable closure performance when subjected to _____ fpm velocity across the face of the damper using the UL 555 fire exposure test.

Options:

A.

75

B.

100

C.

150

D.

200

Question 8

Given: single-wall vent, which serves only one appliance, and has a height of 10 feet.

The maximum horizontal length permitted for a 5-inch diameter vent connector serving this vent is _____ feet.

Options:

A.

5

B.

7.5

C.

9

D.

10

Question 9

ERV systems shall not be installed in which of the following except:

Options:

A.

systems utilizing coil-type exchangers.

B.

common exhaust systems for clothes dryers.

C.

exhaust systems emitting corrosive materials.

D.

equipment designed to assist in the evacuation of occupants.

Question 10

Given: A recirculating industrial direct-fired makeup air heater has a rated input of 200,000 Btu/h . Ventilation air is supplied by separate mechanical means.

Outside ventilation air shall be provided to supply at least _____ CFM.

Options:

A.

250

B.

400

C.

800

D.

1250

Question 11

When a permit is issued, the code requires that one set of approved plans and specifications be returned to the applicant.

This set of plans and specifications shall be:

Options:

A.

kept on the building site.

B.

returned to the architect.

C.

filed with the county clerk or jurisdiction to properly record the property.

D.

retained by the applicant for at least one year after the job is finished in the event modifications are made.

Question 12

A low-pressure steam heating boiler is a boiler furnishing a maximum steam pressure of _____ psi.

Options:

A.

[option text not fully visible in the material you sent]

B.

15

C.

[option text not fully visible in the material you sent]

D.

80

Question 13

Unless listed for a greater or smaller dimension, mechanical draft venting systems shall terminate a minimum of _____ feet below an openable window.

Options:

A.

1

B.

4

C.

8

D.

12

Question 14

Floor furnaces shall not be closer than _____ inches to the ground.

Options:

A.

[option text not fully visible in the material you sent]

B.

[option text not fully visible in the material you sent]

C.

[option text not fully visible in the material you sent]

D.

12

Question 15

Given: a six-story, sprinklered, multifamily building with a continuously ventilated shaft extending vertically from the first floor to the roof and used for exhaust.

Which of the following requirements must also be met?

Options:

A.

kitchen exhaust that penetrates the shaft without a fire damper and extends vertically 12 inches.

B.

fire dampers are installed that are connected to an emergency generator rated for 1 hour.

C.

have steel subducts with wall thickness of 0.0186 inch extending 22 inches horizontally into the shaft.

D.

kitchen exhaust that penetrates the shaft without a fire damper and extends vertically 22 inches.